Domaines d’application

surveiller, protéger, mesurer, commander

Application ferroviaire – Embarqué

  • Voltage detection AC 3 Phases – FT52409

    Voltage detection AC 3 Phases

    FT52409

    Installed on United states AEM-7 locomotives, the relay is used to check presence of the 3-phase 480 V-60 Hz which supply the air compressors, air conditioning units and motor blowers.

    More information Datasheet
  • Fan control current - FT52449

    Fan control current

    FT52449

    On rolling stock, this relay is used to control the cabin air heater fan function. Installed on the Z2N French locomotives.

    More information Datasheet
  • Overload motor current – FT52275

    Overload motor current

    FT52275

    This relay is used to monitor any current overload at primary circuit of the rectifier of the auxiliary motors. Installed in the Korean TGV

    More information Datasheet
  • Differential ground fault detection, high load – FT51172:

    Differential ground fault detection, high load

    FT51172

    On on-board application you have no direct access to the ground, therefore a differential current relay is used to detect leakage by comparing incoming and outgoing power traction circuit lines. It is mounted on BB26000 Locomotives. Moreover, a 11 kAdc overload current relay is mounted on the main busbar to trip the main breaker and thus prevent a global overload in the locomotive.

    More information Datasheet
  • Catenary Voltage detection AC – FT52401

    Catenary Voltage detection AC

    FT52401

    This relay is installed on the primary circuit catenary. It is used to detect the presence of the catenary voltage (overhead wires). Both Pick up and drop out can be delayed to prevents intermittent tripping from momentary pantograph disconnection.

    More information Datasheet
  • Catenary Voltage detection DC – FT52402

    Catenary Voltage detection DC

    FT52402

    This relay is installed on the primary circuit catenary. It is used to detect the presence of the catenary voltage (overhead wires). Both Pick up and drop out can be delayed to prevents intermittent tripping from momentary pantograph disconnection.

    More information Datasheet
  • Battery voltage monitoring – FT52315

    Battery voltage monitoring

    FT52315

    This relay is used on rolling stock to monitor the discharge level of the battery. When the relay is triggered, information is sent to switch the battery charger until the charging voltage is reached. Installed on the SNCF network, Z2N and MI2N locomotives.

    More information Datasheet
  • Overload current braking - FT51474

    Overload current braking

    FT51474

    This current relay is used on rolling stock for detecting an overload current in the braking current circuit.

    More information Datasheet
  • Single phase overload current – FT52486

    Single phase overload current

    FT52486

    This relay is used to detect overload and short circuit in power equipment installed on board In rolling stock it is installed on the primary transformer in line with a current transformer to detect an overload and trip the main breaker. It can also be mounted between the traction rectifier and inverter. Used on French TGV (TGV Atlantic, TGV-R Dual current, TGV-R Three courant), it detects all short circuit seen from the secondary side of the power transformer.

    More information Datasheet
  • Voltage detection – FT51311

    Voltage detection

    FT51311

    Overvoltage detection relay on auxiliary circuit is installed i.e. in TGV to prevent from any kind of overvoltage on DC auxiliary systems. It is installed in TGV-Atlantic.

    More information Datasheet
  • Maximum current detection – FT50587

    Maximum current detection

    FT50587

    On rolling stock, this relay is mounted ahead of the main circuit breaker to detect a global overload in the locomotive. It is Installed on many French locomotives such as BB7200, BB 22200 and TGV-PSE.

    More information Datasheet
  • Ground fault detection differential – FT52112 / FT52471

    Ground fault detection differential

    FT52112 FT52471

    This relay is installed on the primary circuit catenary. It is used to detect the presence of the catenary voltage (overhead wires). Both Pick up and drop out can be delayed to prevents intermittent tripping from momentary pantograph disconnection.

    More information Datasheet FT52471 Datasheet FT52112



Application ferroviaire – Infrastructure

  • Pilot line monitoring – FT52126-MK

    Pilot line monitoring

    FT52126

    For trackside, this relay checks the integrity of a telecom line and detects losses. It is directly supplied by telecom lines between stations. The relays are very low power consumers and can operate several in parallel over few km. Some options like choice of housing, Led for operating state and mounting bracket are available.

    More information Datasheet
  • Return current monitoring – FT52490

    Return current monitoring

    FT52490

    This relay is mounted on a current shunt. The milivoltmetric signal feeds the primary circuit of the relay which is polarized. The relay then makes it possible to pick up in only one polarity. It can be used in the event of a failure of a power diode in a substation cell. Many options like hold memory fault are available.

    More information Datasheet
  • Overload current - FT52473

    Overload current

    FT52473

    There are many applications in trackside equipment. In this example, overload current relay is installed in RATP (Paris Subway) cubicles to check the load passing through the switch gear. the relay can detect an 11 KAdc overcurrent. Hold memory fault option is integrated as well as a Rearming coil for distance operation. More information Datasheet

  • Ground fault detection – FT50832 / FT52165 / FT53021 / FT53043

    Ground fault detection

    FT50832 FT52165 FT53021 FT53043

    For trackside, this ground fault detection relay measures DC current from frame to ground. Mainly installed in Metro and tramways substation, the relay is connected between the ground and the substation frame. If an insulation breakdown occurs the fault current flows through the relay which picks it up. No auxiliary power is needed. As an option, a permanent magnet Gives to the relay the capacity of staying latched even if the fault disappears, a top button allows manual reset. Thanks to this option, the relay can detect both AC and DC current. In options, we propose a relay with remote reset (FT53021 type) and a polarized relay (FT53043 type).

    More information Datasheet FT50832Datasheet FT52165 Datasheet FT53021 Datasheet FT53043
  • Catenary voltage detection – FT53025/26/27

    Catenary voltage detection

    FT53025/26/27

    For trackside, in DC applications (750 | 1500 | 3000 Vdc), this relay is used to detect the presence of catenary voltage into the cubicles from the rectifier. High insulation resistance (up to 12 KV 50hz) provides great resistance to overvoltage, especially natural ones (lightning). Moreover, no auxiliary power is needed.

    More information Datasheet FT53025 Datasheet FT53026 Datasheet FT53027
  • Ground fault detection – FT50832 / FT52165 / FT53021 / FT53043

    Ground fault detection

    FT50832 FT52165 FT53021 FT53043

    For trackside, this ground fault detection relay measures DC current from frame to ground. Mainly installed in Metro and tramways substation, the relay is connected between the ground and the substation frame. If an insulation breakdown occurs the fault current flows through the relay which picks it up. No auxiliary power is needed. As an option, a permanent magnet Gives to the relay the capacity of staying latched even if the fault disappears, a top button allows manual reset. Thanks to this option, the relay can detect both AC and DC current. In options, we propose a relay with remote reset (FT53021 type) and a polarized relay (FT53043 type).

    More information Datasheet FT50832Datasheet FT52165 Datasheet FT53021 Datasheet FT53043
  • Ground fault detection – FT50832 / FT52165 / FT53021 / FT53043

    Ground fault detection

    FT50832 FT52165 FT53021 FT53043

    For trackside, this ground fault detection relay measures DC current from frame to ground. Mainly installed in Metro and tramways substation, the relay is connected between the ground and the substation frame. If an insulation breakdown occurs the fault current flows through the relay which picks it up. No auxiliary power is needed. As an option, a permanent magnet Gives to the relay the capacity of staying latched even if the fault disappears, a top button allows manual reset. Thanks to this option, the relay can detect both AC and DC current. In options, we propose a relay with remote reset (FT53021 type) and a polarized relay (FT53043 type).

    More information Datasheet FT50832Datasheet FT52165 Datasheet FT53021 Datasheet FT53043

Autres

Industrie

Aéronautique

Energie

Appareillage électrique

Application militaire

Appareils de mesure

Electronique

Implantation mondiale de nos relais

Algérie
Allemagne
Arabie Saoudite
Argentine
Australie
Belgique
Brésil
Cameroun
Canada
Chili
Chine
Colombie
Congo
Corée du Sud
Côte d’Ivoire
Egypte
Espagne
Ethiopie
Finlande
France
Gabon
Ghana
Grèce
Inde
Indonésie
Irak
Iran
Irlande
Israël
Italie
Jamaïque
Luxembourg
Madagascar
Malaisie
Mali
Maroc
Mauritanie
Mexique
Mozambique
Norvège
Mauritanie
Mexique
Mozambique
Norvège
Nouvelle-Calédonie
Ouganda
Pays-Bas
Pologne
Portugal
Roumanie
Royaume-Uni
Russie
Singapour
Slovénie
Sri Lanka
Suède
Syrie
Taïwan
Thaïlande
Tunisie
Turquie
Uruguay
USA
Venezuela
Vietnam
Implantation mondiale de nos relais